To enable Gateway to communicate with remote partners, you require one or more Remote Site objects.
When you install Gateway, the software creates a set of Remote Sites adapted for use with different protocols, and enters these sites in your database. The procedure in this topic describes how to add your own Remote Sites.
Field | Description |
---|---|
Alias | Enter an alias for the Remote Site object |
Protocol |
Select the protocol type that you will use for exchanges with this site. When you select a protocol, the set of available tabs changes dynamically. |
Role | |
Initiator/Sender | Select one or more roles for the Remote Site in message exchanges |
Initiator/Receiver | |
Responder/Sender | |
Responder/Receiver |
Field | Description |
---|---|
Maximum data block size (in bytes) |
Specify the maximum data block size in bytes. Integer: 128 - 8000. Default = 4000 |
Maximum number of simultaneous connections to this Site |
Specify the maximum number of connections to this Site. Integer: 0 - 999. Default = 1. For POP3 Sites, this value is always set to 1. |
Maximum number of simultaneous connections from this Site |
Specify the maximum number of connections from this Site. Integer: 0 - 999. Default = 1. For POP3 Sites, this value is always set to 0. |
Maximum number of connection retries before time limit |
Specify the maximum number of times the software tries to connect before stopping the Site. Integer: 0 - 999. Default = 10. |
Time before first retry (in seconds) |
Specify the minimum delay before the first connection retry. Integer: 1 - 9999. Default = 10. Each subsequent retry doubles the time that you enter here. For example, if you enter 10 seconds, the first retry occurs after 10 seconds, the second after 20 seconds, the third after 40 seconds, and so on until either:
|
Maximum interval between retries (in seconds |
Specify the maximum interval between connection retries. The value that you enter here must be greater than or equal to the value entered in the Time before first retry field. Integer: 1 - 9999. Default = 1800. For example, if you enter 30 in this field, 10 in the Time before first retry field and 10 in the Maximum number of connection retries field, then the first retry occurs after 10 seconds, the second after 20 seconds and the third after 30 seconds since this is the maximum interval allowed. Each subsequent retry occurs after 30 seconds until the maximum number of retries is reached, in this case 10. |
Sentinel: Transfer Filter |
Use this option to send a record of Transfer state changes to Sentinel. Select one of the following:
|
Field |
Description |
---|---|
Communication address |
You can define up to four communication addresses for the Remote Site. You must define the properties for the Main address first. To view an existing definition, or define the properties for a new address, select one of the communication paths used to connect to the Site:
|
Network type |
Select one of the following:
The fields displayed in the right pane depend on the type of network that you select in this field. |
Initial communication path |
This field displays the initial address used to connect to the Site. By default this field is set to Main address and is grayed out. However, if an error occurs on the Main address, you can select another communication address from the drop-down list. |
Right pane - X.25 specific fields: |
|
Called address |
Specify the destination network address for the Remote Site. |
Calling address |
Specify the originator network address for the Site. |
User data in the call request packet |
Maximum: 18 hexadecimal characters. |
Facilities |
Enter a hexadecimal string with facility services in the format <code><value>. The supported facility services are:
|
Logon message |
PEL and PeSIT protocols only Enter a message to send before the protocol exchange. Use this message to specify the target Application.
|
Logon code |
Select one of the following codes for the logon message:
|
Right pane - TCP/IP specific fields:
|
|
IP address or machine name |
Enter the IP address. |
Port number |
Enter the port number. |
Network Proxy |
This field displays a list of Proxies whose protocol is either SOCKS4 or HTTPS. This field is available for all protocols. Select a Proxy from the drop-down list. |
FTP Proxy |
FTP and HTTP only This field displays the list of available FTP or HTTP Proxies. Select a Proxy from the drop-down list. |
Right pane - LU 6.2 specific fields: |
|
Destination (mandatory) |
Enter the CPI-C symbolic destination defined in the SNA configuration database. The symbolic destination identifies the SNA resources to use to connect to the Remote Site. This field contains a definition of all the other parameters on this tab. Any values that you enter in the other fields on this tab will override the values in the CPI-C symbolic destination. |
User identification |
Enter the login user ID. |
Password |
Enter the login user password. |
Type |
Enter the conversation type. This version of the product supports Basic Conversation only. |
Mode |
Enter the LU 6.2 mode name to use. The Mode Name determines the session parameters to use. |
LU Partner |
Enter the Logical Unit for the Remote partner. |
LU Local |
Enter the Logical Unit for the Local partner. |
Transaction |
Enter the name of the CPI-C Transaction program that you want to invoke. |
PIP |
Enter the Program Initialization Parameters. |