KB Article #179465
Server transfer randomly abort with a code 730 ABO 300
Problem
Error on CFT side:
CFTH13E FPDU Remote reject <PART=My_ConnectExpress_partner DIAGI=730 DIAGP=ABO 300>
Error on Connect:Express side: code 730 ABO 311
ABORT -> YVAL3280 SRC=0001 TRC=0000L PRC=3300
Resolution
Check the CFT parameters so PROF CFT is not used when in front a C:X partner
Check the partner properties so PeSIT E is used.
PROF = ANY must be used when the partner is Connect Express
On C:X side, check the session table/partner properties and verify the PeSIT version E is used