KB Article #43378

The processes of CFT cannot start if the "Security Level" of the OS400 has been changed

Problem

The processes of CFT cannot start  if the  "Security Level" of the OS400 has been changed
Error message :
Erreur SIMULTI -100  -02 FFFFF5 UNABLE  TO CREATE  NEW   CTLBLK.


Resolution

If  the "Security Level" of the OS400 has changed, by example : Level 30 to 40, it is necessary to  execute the command : INSTALL (F4) and ENTER.  
This command create some objets which are differents according to the "Security Level" of the OS400.