KB Article #65686
Transfer Request From CFT to Gateway Fails With Error "Invalid remote identifier"
Environment
-------------------------
CFT initiator, Gateway receiver
Gateway version 6.9.1
Problem
------------------------
* Transfer request CFT -> Gateway fails with error "Invalid remote identifier"
* Configuration done according to XFB Monitor CFT_XFB Gateway_InteroperabilityGuide_ENG.pdf
https://support.axway.com:443/WSD/pub/2051
* Verified the CFT parameters NSPART corresponds to the Gateway remote site protocol ID and the NRPART to correspond to the local site protocol ID
Resolution
CFT Configuration
-----------------------------
-- Do not use PESIT PROFIL CFT which is CFT specific
-- Use PESIT ANY ( TYPE=PESIT PROF=ANY )
Gateway Configuration
-------------------------------------
-- Check the remote site used for the CFT partner, PESIT tab
-- Make sure you do not have some values for the section "Preconexion Phase" - leave them blank
-- In the section "Connection Phase" add the values of the NSPASSW and NRPASSW used by your partner
--Client « password to check » (Gateway) has to correspond to NSPASSW (CFT) and
Client « password to send » has to correspond with NRPASSW.