SUBJECT
"connexion en mode serveur refusee: raison="14, Identificateur distant invalide"
PROBLEM
--CFT sending to InterPel
--Error received:
20120704 135644 102 NET I CONN_IND (8239) indication de connexion entrante [src_address="10.248.52.248/12170"] [dest_address="192.168.102.98/6330"] 20120704 135644 011 SECS I SES_INIT (48242735) NetProf : DEFAULT selectionn. [src_add="10.248.52.248/12170"] [dest_add="192.168.102.98/6330"] 20120704 135644 103 NET I CONN_RESP (8239) reponse connexion entrante [resp_address="10.248.52.248/12170"] 20120704 135644 024 FPSIT I CONN_IND OP DP001203(2350) [0] demande de connexion recue pour OP PROSOCFT 20120704 135644 004 SUP I INIT_RP- (44042542) connexion en mode serveur refusee: raison="14, Identificateur distant invalide" 20120704 135644 106 NET I DISC_IND (8239) indication de deconnexion [reason="0"] [origin="0"]
RESOLUTION
- Clearly specify protocol/connector between CFT and InterPel
cftpart id= PROSOCFT, prot= PROTTCP, SYST= WIN95, sap=6330, nspart = DP001203,--->Corresponding to the local on CFT nrpart = PROSOCFT,--->Corresponding to the remote on Gateway| What caused the issue? Why? prof=CFT of cftprot
- Set the PROF parameter to ANY
|