KB Article #177801

disabling the Application Pickup type Trigger / Trigger (polling) does not stop the execution of the trigger

Problem

-- need to disable an application pickup

-- AP type is trigger or trigger (polling), based on a JMC or MBC

-- disabling the trigger does not stop the execution of the trigger (in case of polling, the trigger keeps getting data)

Resolution

* this is a known issue. Interchange does not send the signal to Integrator (where the trigger is running)

* the problem is solved in B2Bi 2.1 SP7 and higher