KB Article #178593
PROCESS_START: failed to start process "Dummy": The system cannot find the file specified
Problem
-- Interchange cannot connect to Integrator
2017-04-19 09:09:22,895 - ERROR [qtp915207865-329] (MessageExecutionWrapper.execute:33) - There was an error while executing message id 999 from node axw_cn
b2bx.server.B2BXException: No connection to Integrator. Could not get all Application types for : delivery
-- getting this error in Integrator/data/starter.log
PROCESS_START: failed to start process "Dummy": The system cannot find the file specified
Resolution
* it is probably related to permission issues on the shared directory
* open Integrator trace file of the day when B2Bi has ben installed and look for "permission denied"
ERROR :20170419:08.24.27.97:cfgserver(cfgembed(cfgmbc_archiver)):cfgmbc_archiver.s4:434:UTIL_FILEPERM: failed to set file permissions for file "\opt\axway\Prod\local\config\archiver\archiverscript_1.bat": Permission denied
* if there are permission issues, uninstall B2Bi, set the permissionon the shared directory and stated in the installation guide, and reinstall B2Bi