KB Article #188642
Not able to send message from B2Bi to CFT (SERVER AUTHENTICATION FAILED)
Problem
-- If you want to send messages from B2Bi to CFT and you have the below error:
ABORT REQUEST: code=399 text=SERVER AUTHENTICATION FAILED -- ABORT INDICATION RECEIVED: code=399 text=SERVER AUTHENTICATION FAILEDResolution
-- The problem could come from the wrong password set in PESIT Partner Delivery or PESIT Trading Pickup, try to uncheck:
Use Password (this is the password the partners expect)
and
Use Password (this is the password expected from the partners)
(THE ABOVE INFORMATION IS APPLICABLE IN THE CASE WHEN CFT IS NOT USING THE PASSWORD FOR THE AUTHENTICATION)