KB Article #73860
Broadcast Error message after importing Integrator server
-- Example error:
2010/07/13 11:31:13 :: --------------------------------------------------------------------------------
2010/07/13 11:31:13 ::
2010/07/13 11:31:13 :: SEND TO PRODUCTION
2010/07/13 11:31:13 ::
2010/07/13 11:31:13 :: User : NL20819/thread#0
2010/07/13 11:31:13 ::
2010/07/13 11:31:13 :: -Object
2010/07/13 11:31:13 :: .Type : XSoftwareXib300Unix
2010/07/13 11:31:13 :: .Name : Integrator_DEVAS[Company.Integrator_DEVAS]
2010/07/13 11:31:13 :: -Object
2010/07/13 11:31:13 :: .Type : Host
2010/07/13 11:31:13 :: .Name : DEVAS[Company.DEVAS]
2010/07/13 11:31:13 :: -Object
2010/07/13 11:31:13 :: .Type : Net
2010/07/13 11:31:13 :: .Name : TCP[Company.TCP]
2010/07/13 11:31:13 ::
2010/07/13 11:31:14 :: Unknown error : Integrator Server is waiting for Synchrony Server with the physical name <35e035c6-5727-
11dd-ad01-005056c00008>. An Integrator Server can't be represented by more than one Synchrony Server in the Composer.
Resolution
* Steps:
1.Modify the file agent.properties which is at : Synchrony\Integrator\local\broadcastagent , and add this line at the end :delete.all.relations=true
2.Restart the Integrator Server.
3.Stop the Integrator tasks and choose Integration Services Workbench,then Integrator Server-->Tools--> Integration--> clean server.
4.Do an import-object-set from Topography Workbench (right click on the Integrator Server) in order to import again the configuration of Integrator to Composer. There should be no errors.